LBH288

48 Hours VH2O2 or Plasma Biological Indicator for Sterilization Monitoring
• Dramatic color change
• Reduced incubation time accuracy > 97%
• LISTER’s proprietary fluorescence technology
• Unmatched accuracy from LISTER
• Cutting-edge, updated enzyme technology
• Lower false-positive rate 

48 hour VH2O2 Process bio Indicator for sterilization

Specification

PERFORMANCE CHARACTERISTICS


BrandLISTER
Processplasma or vaporized Hydrogen  Peroxide
MicroorganismGeobacillus Stearothermophilus
Population3☓10⁵ to 1☓10⁷  CFU/pcs
Read-Out Time48 hour



Resistance

D value / s5 ~ 80
Survival / s100 ~ 300
Kill / s100 ~ 800
RIT(reduced incubation time accuracy)≥97%

Test condition

50 ℃ ± 0.5 ℃

H₂O₂ 2.3 ± 0.4 mg/L




TECHNICAL INFORMATION


Label color changeBefore:green; After:yellow;
Color of culture mediumPositive:yellow; Negative:purple;
Quality of culture medium0.5-0.6ml
Weight of BI2.1-2.2g/pcs
Period of validity24 months


Dimensions

10.9 mm (cap diameter)
8.8 mm (pipe diameter)
46 mm (height)


Regulations

ISO 11138-1:2017
ISO 11140-1:2014
Package100 pcs/box 



Product Information

Product Name and Code



Biological Indicator For plasma or vaporized Hydrogen  Peroxide sterilization processes – LBH288


Features & Advantages



      • 48 hour results

      • Dramatic color change

      • Kit includes both BI ampoules and culture media tubes

      • Reduced incubation time accuracy > 97%

      • LISTER’s proprietary fluorescence technology

      • Unmatched accuracy from LISTER

      • Incorporating cutting-edge, updated enzyme technology

      • Lower false-positive rate compared to other biological indicators


Indications for Use



The LBH288 is utilized to monitor the efficacy of H2O2 plasma sterilization cycles.


Related Document Download



     48 hour VH2O2 Process bio Indicator for sterilizationTechnical Data Sheet  LBH288.pdf

    48 hour VH2O2 Process bio Indicator for sterilizationProduct Brochure of Biological Indicators.pdf


Product Description


Biological Indicator | Bowie Dick Test Pack |  Sterilization Process Challenge Device | LISTER BIOMEDICAL CO.,LTD

Self-Contained Biological Indicators consist of:


A plastic pipe and cap. The cap with a hole is placed on top of the pipe to allow

 the sterilizing agent to penetrate into the indicator. 

Between pipe and cap there is a filter paper which is used to avoid pollution. 


A crushable media ampule which contains modified culture medium with a pH 

indicator. The modified culture medium will change from the initial Purple color to 

Yellow in the presence of bacterial growth. 


An inoculated carrier of Geobacillus stearothermophilus ATCC 7953 is located at 

the bottom closed end of the pipe.


The LBE288 Biological Indicator, when used with an incubator 

(incubation temperature 56-60°C), provides a test result after 24 hours.


The label on the outside of the plastic pipe contains a Type 1 chemical indicator strip.