20 mins Ultra Super Rapid Biological Indicator For Steam sterilization processes
• 20 min results • Rapid Fluorescence and exact results • Reduced incubation time accuracy > 97% • Dramatic color change • Kit includes both BI ampoules and culture media tubes
20 mins Ultra Super Rapid plasma or VH2O2 Biological Indicator
20 mins Ultra Super Rapid Biological Indicator For Steam sterilization processes
20 mins Ultra Super Rapid Formaldehyde Sterilization Biological Indicator
3-hour Self-Contained Biological Indicator for VH2O2 Plasma Sterilization
48 Hours VH2O2 or Plasma Biological Indicator for Sterilization Monitoring
24-hour Plasma or Vaporized Hydrogen Peroxide sterilization Biological Indicator
48 hours Ethylene Oxide Sterilization Biological Indicator
1 hour Super Rapid Plasma or VH2O2 Sterilization Biological Indicator
A clean and sanitized office signifies the right level of professionalism and tells potential customers that the company takes pride in its brand and employees. Leverage agile frameworks.
Brand | LISTE | |
Process | Steam | |
Microorganism | Geobacillus Atrophaeus | |
Population | 10^6 Spores/carrier | |
Read-Out Time | 20 min | |
Resistance | 121℃ D value / m | 1.5 to 4 min |
121℃ Survival / m | 5 to 15 min | |
121℃ Kill / m | 18 to 40 min | |
132℃ D value / m | 0.15 to 0.7 min | |
134℃ D value / m | 0.1 to 0.6min | |
Z value | 8 to 30℃ | |
RIT(reduced incubation time accuracy) | ≥97% | |
Test condition | 121℃; 132℃; 134℃ Saturated steam with pre-vacuum |
Label color change | Before: pink; After: black; |
Color of culture medium | Positive:yellow; Negative:purple; |
Quality of culture | medium0.5-0.6ml |
Weight of BI | 2.3-2.4g/pcs |
Period of validity | 24 months |
Dimensions | 10.9 mm (cap diameter) |
8.6 mm (pipe diameter) | |
57 mm (height) | |
Regulations | ISO 11138-1:2017 |
ISO 11138-2:2017 | |
ISO 11138-8:2021 | |
ISO 11140-1:2014 | |
Package | 50 pcs/box |
· 20 min results
The LBS020 is utilized to monitor sterilization efficacy of gravity displacement or vacuum-assisted steam processes at 132°C to 135°C.
Product Brochure of Biological Indicators.pdf
Technical Data Sheet LBS020.pdf
SELF-CONTAINED BIOLOGICAL INDICATORS Key Components ✅ Cap and Filter Paper The plastic cap has a small hole to allow sterilizing agents to penetrate the indicator. A filter paper placed between the cap and the pipe prevents contamination. ✅ Crushable Media Ampule Contains a modified culture medium with a pH indicator and fluorogenic substrates. In the presence of bacterial growth, the medium changes color from Purple to Yellow. ✅ Inoculated Carrier Contains Geobacillus stearothermophilus (ATCC 7953) spores. Positioned at the bottom, inside the sealed end of the pipe. ✅ Barrier Acts as a plug between the carrier and the ampule, ensuring separation and integrity. ✅ External Label A Type 1 chemical indicator strip is affixed to the outside of the pipe for easy identification of processing conditions. The LBS020 Biological Indicator, when used with an automatic reader (incubation temperature 56-60°C),provides a fluorescence test result in just 20 minutes with an accuracy of ≥97%. For additional confirmation, users can continue incubation for 48 hours to visually confirm the culture medium's stability or color change. |